dc.identifier.citation | Yakhshiboev Sh.K., Ergashev Sh.H., Eshkulov J.O. Theoretical and practical research on thermal energy efficiency and energy audit of the building of the “Energy” faculty of Karshi State Technical University. Alternative energy. 2025. 1(16). pp. 132-139. | en_US |
dc.identifier.issn | 2181-2284 | |
dc.identifier.uri | https://dspace.kstu.uz/xmlui/handle/123456789/193 | |
dc.description.abstract | Kirish. Qishki mavsumda bino va inshootlarni issiqlik ta’minotini tizimidagi
mavjud muammolarni bartaraf etish, energiya tejamkor qurilmalarni joriy etish, ular yordamida
isitish tizimini samarali tashkil etish, katta miqdorda energiya resurslarni tejash imkonini beradi.
Usul va materiallar. Mazkur muammoni yechishda bir nechta usullar mavjud bo‘lib, ushbu
ishda dastlab kuzatish, sonli taxlil qilish va qiyoslash usulidan foydalanilgan.
Natijalar. Oʻtkazilgan sonli tahlilar shuni ko‘rsatadiki, bino uchun eng samarador isitish
radiatori va uning turi tanlandi, ularning maksimal soni, binoning shimoliy tomon tashqi devor sirti
uchun eng maqbul issiqlik izolyatsiya materiali tanlandi. Bundan tashqari tashqi havo haroratiga
bog‘liq ravishda binoning issiqlik yuklamasi va o‘rnatilgan isitish qozonining bino yuklamasiga
mosligi aniqlandi.
Xulosa.Tadqiqiot natijasida quyidagi xulosa va takliflar ishlab chiqildi. Agar binoning
shimoliy va janubiy tomoniga qalinligi 3,5 sm bo‘lgan “Penoliuretan”(λ=0,029 Vt/m*0C) markali
issiqlik izolyatsion material bilan qoplansa binoning umumiy issiqlik yuklamasini 18,36%
kamayishiga olib keladi. Agar o‘quv binosidagi mavjud (metall quvurli-35,63 kVt, yaʼni bu binoning
38,8% issiqlik yuklamasini qoplaydi) isitish radiatorlari (akfa alyuminiy-99,6 kVt, yaʼni bu
binoning issiqlik yuklamasini toʻliq(100%) qoplaydi) isitish radiatorlariga almashtirilganda | en_US |
dc.language.iso | other | en_US |
dc.publisher | Muqobil energetika, Intellekt nashriyoti | en_US |
dc.relation.ispartofseries | 01(16)2025; | |
dc.subject | energiya tejamkorligi, energoaudit, temirbeton, gazabeton, keramzit, ruberoid, penoplast, mramor, termik qarshilik, issiqlik o‘tkazuvchanlik, basalt qoplama, akfa alyuminiy, isiqlik yuklamasi | en_US |
dc.title | QARSHI DAVLAT TEXNIKA UNIVERSITETI “ENERGETIKA” FAKULTETI BINOSINING ISSIQLIK ENERGIYA TEJAMKORLIGI VA ENERGOAUDIT BO‘YICHA O‘TKAZILGAN NAZARIY-AMALIY TADQIQOTLAR | en_US |
dc.title.alternative | THEORETICAL AND PRACTICAL RESEARCH ON THERMAL ENERGY EFFICIENCY AND ENERGY AUDIT OF THE BUILDING OF THE “ENERGY” FACULTY OF KARSHI STATE TECHNICAL UNIVERSITY | en_US |
dc.title.alternative | ТЕПЛОЭНЕРГОСБЕРЕЖЕНИЕ И ЭНЕРГОАУДИТ ЗДАНИЯ ФАКУЛЬТЕТА «ЭНЕРГЕТИКА» КАРШИНСКОГО ГОСУДАРСТВЕННОГО ТЕХНИЧЕСКОГО УНИВЕРСИТЕТА | en_US |
dc.type | Article | en_US |